- 电子/电子工程 - by Enrique Cavalitto
- Definition(s)
- Dozvoljena struja opterećenja (kabla) u amperima
Own research - by Mira Stepanovic
- Example sentence(s)
- Predmet: ELEKTROENERGETSKA KABLOVSKA TEHNIKA
Konstruktivni elementi i vrste elektroenergetskih kablova. Električno polje kabla. Električni parametri kabla. Gubici snage kod kablova. Strujna opteretljivost kablova.
Uticaj sredine na strujnu opteretljivost kablova. Strujna opteretljivost pri kratkom spoju. Kablovske završnice i spojnice. - Elektronski fakultet Niš by Mira Stepanovic
- Uticaj termičke nehomogenosti zemljišta na strujnu opteretljivost
Kod određivanja intenziteta termički trajno dozvoljene struje kablova položenih u zemlji obično se polazi od činjenice da je zemljište homogeno sa termičkog aspekta. Međutim, kablovski vod veće dužine može da prolazi kroz zemljište različitih termičkih karakteristika, kao i da se na pojedinim delovima provlači kroz cevi ili kablovice. Zbog toga se u radu analiziraju dva karakteristična slučaja na koje se mogu svesti razni slučajevi u praksi. Određeni su izrazi za raspodelu temperature duž provodnika kabla koji omogućavaju analizu uticaja termičke nehomogenosti na strujnu opteretljivost kabla. Analizom strujne opteretljivosti tri jednožilna kabla XHE 48-A 1x100/95 mm2 110 kV postavljena u snopu, pokazano je da termička nehomogenost zemljišta ima veliki uticaj na vrednost termički trajno dozvoljene struje.
IMPACT OF SOIL THERMAL NON-HOMOGENEITY ON CABLE AMPACITY
In ampacity calculation, for the cables laid in the ground the fact is usually taken into account that the soil is homogeneous from the thermal aspect. However, long cable line can pass through the grounds of different thermal characteristics, or some parts of the cable may pass through the pipes or the ducts. Therefore, this paper analyzes two characteristic cases that represent different practical cases. The equations for
temperature distribution along the cable conductor are derived, which enables analyzing the impact of thermal non-homogeneity on the cable ampacity. The cable ampacity analysis of three single-core cables XHE 48-A 1x100/95 mm2 110 kV in three-phase system bunched, shows that soil thermal non-homogeneity has a great impact on the value of rated ampacity. - Elektroprivreda by Mira Stepanovic
- Koeficijenti uticaja vetra i sunčevog zračenja na strujnu opteretljivost nadzemnih vodova sa Al/č provodnicima - Elektroprivreda by Mira Stepanovic
- Related KudoZ question
- Compare this term in: Croatian克罗地亚语, Albanian阿尔巴尼亚语, Arabic阿拉伯语, Bulgarian保加利亚语, Czech捷克语, German德语, Greek希腊语, English英语, Spanish西班牙语, 波斯语(法尔西语), Finnish芬兰语, French法语, Hindi印地语, Hungarian匈牙利语, Italian意大利语, Japanese日语, Portuguese葡萄牙语, Romanian罗马尼亚语, Russian俄语, Slovak斯洛伐克语, Swedish瑞典语
| | The glossary compiled from Glossary-building KudoZ is made available openly under the Creative Commons "By" license (v3.0). By submitting this form, you agree to make your contribution available to others under the terms of that license. | | | | X Sign in to your ProZ.com account... | | | | | | |