en posición de pie Liquido a perfundir

English translation: in a standing position, using a fluid-perfused catheter// Fluid to be perfused:

22:57 Jun 13, 2017
Spanish to English translations [PRO]
Medical - Medical (general) / CYSTOMETRY, EMG
Spanish term or phrase: en posición de pie Liquido a perfundir
Text:
"Se realiza estudio urodinámico con equipo multicanal en posición de pie Liquido a perfundir: solución salina a temperatura ambiente a una velocidad de 50ml/min"

My try is "with/using liquid to be perfused (or: infused?) at the bottom," but I'm really not sure my interpretation is right.
Seth Phillips
United States
Local time: 08:44
English translation:in a standing position, using a fluid-perfused catheter// Fluid to be perfused:
Explanation:
Evidence Acquisition

A systematic search was conducted in 14 medical databases. Studies comparing urodynamic parameters in standing versus sitting position were eligible for inclusion. Studies were stratified according to health status of included male participants: healthy individuals and patients with LUTS. Standardized mean differences for Qmax, TQ and PVR were pooled in a random effects model.

https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4106761/

The aim of the study was to assess the sensitivity for urodynamic abnormalities of both static and dynamic urethral closure pressure profiles done in the sitting and standing positions.

https://link.springer.com/article/10.1007/BF01892741

Errors in initial measurement of Pdet are common with
microtransducer catheters, fibre-optic sensor transducers,
as well as air-charged catheters, as the ICS reference level
(superior margin of the symphysis pubis) cannot be
determined using this technology; most UDS systems provide
an ‘equalisation’ function that assigns Pabd equal to the value of
Pves, which is the only absolute pressure in UDS; this process
must be repeated when the patient is moved from a supine to
upright (sitting or standing) position.

Source: Urodynamic testing: physiological background,
setting-up, calibration and artefacts

Orit Raz, Vincent Tse*† and Lewis Chan†
Department of Urology, School of Advanced Medicine, Macquarie University, *Macquarie University Hospital and
†Concord Hospital, University of Sydney, Sydney, NSW, Australia


SE UTILIZA "PERFUSE":

https://books.google.com.ar/books?id=3IIqPtg-upwC&pg=PA453&d...

https://books.google.com.ar/books?id=ADz_dEprVTMC&pg=PA378&l...

https://books.google.com.ar/books?id=f-MCDQAAQBAJ&pg=PA1029&...

------------------------------------------------------------------------------

You could also translate this part as "... using a fluid-perfused catheter". This study is carried out using a catheter.


Urethral pressure studies can be done with water perfused catheters or micro-tip catheters. When using water-perfused catheters, solution should be run through the urethral lumen at 4-12 cc/min. This is to provide backpressure for the transducer to measure pressure against.

http://163.178.103.176/Fisiologia/renal/objetivo_10/urodynam...
Selected response from:

Gabriela Alvarez
Argentina
Local time: 09:44
Grading comment
Selected automatically based on peer agreement.
4 KudoZ points were awarded for this answer



Summary of answers provided
3 +2in a standing position, using a fluid-perfused catheter// Fluid to be perfused:
Gabriela Alvarez


Discussion entries: 1





  

Answers


1 hr   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): +2
in a standing position, using a fluid-perfused catheter// Fluid to be perfused:


Explanation:
Evidence Acquisition

A systematic search was conducted in 14 medical databases. Studies comparing urodynamic parameters in standing versus sitting position were eligible for inclusion. Studies were stratified according to health status of included male participants: healthy individuals and patients with LUTS. Standardized mean differences for Qmax, TQ and PVR were pooled in a random effects model.

https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4106761/

The aim of the study was to assess the sensitivity for urodynamic abnormalities of both static and dynamic urethral closure pressure profiles done in the sitting and standing positions.

https://link.springer.com/article/10.1007/BF01892741

Errors in initial measurement of Pdet are common with
microtransducer catheters, fibre-optic sensor transducers,
as well as air-charged catheters, as the ICS reference level
(superior margin of the symphysis pubis) cannot be
determined using this technology; most UDS systems provide
an ‘equalisation’ function that assigns Pabd equal to the value of
Pves, which is the only absolute pressure in UDS; this process
must be repeated when the patient is moved from a supine to
upright (sitting or standing) position.

Source: Urodynamic testing: physiological background,
setting-up, calibration and artefacts

Orit Raz, Vincent Tse*† and Lewis Chan†
Department of Urology, School of Advanced Medicine, Macquarie University, *Macquarie University Hospital and
†Concord Hospital, University of Sydney, Sydney, NSW, Australia


SE UTILIZA "PERFUSE":

https://books.google.com.ar/books?id=3IIqPtg-upwC&pg=PA453&d...

https://books.google.com.ar/books?id=ADz_dEprVTMC&pg=PA378&l...

https://books.google.com.ar/books?id=f-MCDQAAQBAJ&pg=PA1029&...

------------------------------------------------------------------------------

You could also translate this part as "... using a fluid-perfused catheter". This study is carried out using a catheter.


Urethral pressure studies can be done with water perfused catheters or micro-tip catheters. When using water-perfused catheters, solution should be run through the urethral lumen at 4-12 cc/min. This is to provide backpressure for the transducer to measure pressure against.

http://163.178.103.176/Fisiologia/renal/objetivo_10/urodynam...

Gabriela Alvarez
Argentina
Local time: 09:44
Specializes in field
Native speaker of: Native in SpanishSpanish
PRO pts in category: 28
Grading comment
Selected automatically based on peer agreement.

Peer comments on this answer (and responses from the answerer)
agree  Muriel Vasconcellos
15 mins
  -> Thanks Muriel! :-)

agree  Stephen D. Moore: There appears to be a period missing after "...posición de pie", too.
1 day 40 mins
  -> Yes, you're right. Thanks Stephen! :-)
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search